Test Systems
EA-ELR 21000 DTS-01
| Manufacturer | EA - Elektro-Automatik |
| Power | 30.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-01
| Manufacturer |
|
| Power | 30.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-02
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-02
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 381 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-360V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-360V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 60.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BIM 20005
| Manufacturer | EA - Elektro-Automatik |
| Power | 60.00 W |
| Package | Bench mount |
| No. of outputs | 1 |
| Available output range (V) | 0-5V |
EA-BIM 20005
| Manufacturer |
|
| Power | 60.00 W |
| Package | Bench mount |
| No. of outputs | 1 |
| Input voltage | 100-230VAC |
| Efficiency | 0.00 |
| Available output range (V) | 0-5V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 482.6×500.4×133.4mm |
| Water-cooled option | No |
Features:
|
|
| Description: Get fast, accurate insight into Li-Ion battery cell quality by performing electrochemical impedance spectroscopy measurements (EIS) on up to 20 channels with the industry’s highest throughput. Included software, industry-standard interfaces and low power consumption make it easy to integrate this battery impedance tester into your workflow. |
|
| Download datasheet |
EA-ELR 21000 DTS-03
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-03
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 382 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-360V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-360V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 90.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-04
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-04
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 383 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-360V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-360V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 24U
| Manufacturer | EA - Elektro-Automatik |
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 24U
| Manufacturer |
|
| Power | 120.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-05
| Manufacturer | EA - Elektro-Automatik |
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-05
| Manufacturer |
|
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 384 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 150.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-06
| Manufacturer | EA - Elektro-Automatik |
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-06
| Manufacturer |
|
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 385 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 180.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-07
| Manufacturer | EA - Elektro-Automatik |
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-07
| Manufacturer |
|
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 386 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 210.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-08
| Manufacturer | EA - Elektro-Automatik |
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-08
| Manufacturer |
|
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 387 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-750V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-750V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 240.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 300.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1000V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 300.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1000V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-BTS 10300 42U
| Manufacturer | EA - Elektro-Automatik |
| Power | 300.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-1500V |
EA-BTS 10300 42U
| Manufacturer |
|
| Power | 300.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 380–480 VAC |
| Efficiency | 95.60 |
| Available output range (V) | 0-1500V |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The EA-BTS 10300 provides a complete solution for battery cycling and testing. Tests include drive cycle simulations and insulation resistance in addition to battery cycling. The system can control an environmental chamber and interface to the battery management system through the CAN bus interface. The widget-based system software enables quick and easy test setup and execution. |
|
| Download datasheet |
EA-ELR 21000 DTS-16
| Manufacturer | EA - Elektro-Automatik |
| Power | 480.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-16
| Manufacturer |
|
| Power | 480.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 388 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-24
| Manufacturer | EA - Elektro-Automatik |
| Power | 720.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-24
| Manufacturer |
|
| Power | 720.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 389 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-32
| Manufacturer | EA - Elektro-Automatik |
| Power | 960.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-32
| Manufacturer |
|
| Power | 960.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 390 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-40
| Manufacturer | EA - Elektro-Automatik |
| Power | 1200.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-40
| Manufacturer |
|
| Power | 1200.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 391 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-48
| Manufacturer | EA - Elektro-Automatik |
| Power | 1440.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-48
| Manufacturer |
|
| Power | 1440.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 392 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-56
| Manufacturer | EA - Elektro-Automatik |
| Power | 1680.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-56
| Manufacturer |
|
| Power | 1680.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 393 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-ELR 21000 DTS-64
| Manufacturer | EA - Elektro-Automatik |
| Power | 1920.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0–1000 VDC |
EA-ELR 21000 DTS-64
| Manufacturer |
|
| Power | 1920.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 394 - 480 V, ±10%, |
| Efficiency | 95.00 |
| Available output range (V) | 0–1000 VDC |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650.00 |
| Water-cooled option | No |
Features:
|
|
| Description: The ELR 21000 dynamic test system provides a highspeed solution for testing next-generation data center power supplies. The system operates as a regenerative electronic load, returning energy to the microgrid with efficiencies of up to 95%. With DC power of up to 1920 kW, a DC voltage range of 0 to 1000 V, and DC current capability of up to 5120 A, the system is designed for testing high-dynamic power shelves used in data center power infrastructure. It enables engineers to evaluate compliance with the requirements of emerging 800 V data center power architectures. |
|
| Download datasheet |
EA-BCTS 20010-600-18
| Manufacturer | EA - Elektro-Automatik |
| Power | 6000.00 W |
| Package | 42U |
| No. of outputs | 18 |
| Available output range (V) | 0-10 |
EA-BCTS 20010-600-18
| Manufacturer |
|
| Power | 6000.00 W |
| Package | 42U |
| No. of outputs | 18 |
| Input voltage | 400 V, ±10% 3-phase |
| Efficiency | 0.00 |
| Available output range (V) | 0-10 |
| Output current (A) | 0-600 |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1200mm |
| Weight | 650 |
| Water-cooled option | No |
Features:
|
|
| Description: The BCTS 20010-600-18 provides 18 individual channels for high current cell testing. Each channel works as a cell cycler device which can perform the function of charging and discharging. In discharge mode the device is regenerative and feeds the energy back into the local grid with an efficiency of up to 90.5%. The DC voltage of 0 - 10 V and the current of 0 - 600 A of each channel is tailored for the testing of high capacity battery cells. Each channel is equipped with a DC contactor to clearly separate the battery cell from the channel and to enable additional, useful functionalities. These include the active pre-charge, the reverse polarity detection and the zero current turn off functionality. In addition, each channel has a temperature input to monitor the temperature of the cell under test and to stop the test if the cell becomes too hot. The channels are installed with a high density into a 42U rack that has a width of only 600 mm and a depth of 1200 mm. The Rack has one AC input and is equipped with a 2-channel fast stop chain to shut down the rack in emergency situations. The fast stop button is placed on the front of the door and the rear door is secured by door contact switches. Once the rear door opens during operation the fast stop chain will be activated automatically. Also, the DC contactors are integrated into the fast stop chain and disconnects the cell tester from the cells under test. |
|
| Download datasheet |
EA-BMTS 20200-840-2
| Manufacturer | EA - Elektro-Automatik |
| Power | 60000.00 W |
| Package | 42U |
| No. of outputs | 2 |
| Available output range (V) | 0-200 |
EA-BMTS 20200-840-2
| Manufacturer |
|
| Power | 60000.00 W |
| Package | 42U |
| No. of outputs | 2 |
| Input voltage | 401 V, ±10% 3-phase |
| Efficiency | 95.30 |
| Available output range (V) | 0-200 |
| Output current (A) | 0-840 |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 600 |
| Water-cooled option | No |
Features:
|
|
| Description: The BMTS 20200-840-2 provides 2 individual channels for high capacity battery module testing. Each channel works as a cycler device which can perform the function of charging and discharging. In discharge mode the device is regenerative and feeds the energy back into the local grid with an efficiency up to 95.3%. The DC power of 60 kW, the DC voltage of 0 - 200 V and the DC current of 0 - 840 A of each channel is tailored for the testing of high capacity battery modules. Each channel is equipped with DC contactors (one in DC+ and one in DC-) to clearly separate the battery module from the system and to enable additional, useful functionalities. These include the active pre-charge, the reverse polarity detection and the zero current turn off functionality. In addition, each channel has a temperature input to monitor the temperature of the battery module under test and to stop the test if the battery module becomes too hot. The system is installed with a high density into a 42U rack that has a width of only 600 mm and a depth of 1000 mm. The Rack has one AC input and is equipped with a 2 channel fast stop system to shut down the rack in emergency situations. The fast stop button is placed on the front of the door and the rear door is secured by door contact switches. Once the rear door opens during operation the fast stop system will be activated automatically. Also, the DC contactors are integrated into the fast stop system and disconnects the module tester from the battery module under test |
|
| Download datasheet |
EA-FCTS 20920-720
| Manufacturer | EA - Elektro-Automatik |
| Power | 180000.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-920 |
EA-FCTS 20920-720
| Manufacturer |
|
| Power | 180000.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 403 V, ±10% 3-phase |
| Efficiency | 0.00 |
| Available output range (V) | 0-920 |
| Output current (A) | 0-720 |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650 |
| Water-cooled option | No |
Features:
|
|
| Description: The FCTS 20920-720 provides a powerful system for high power fuel cell testing. The system works as an electronic load to discharge and stimulate fuel cells. The system is regenerative and feeds the energy back into the local grid with an efficiency up to 96.5%. The DC power of 180 kW, the DC voltage of 0 - 920 V and the DC current of 0 - 720 A is tailored for the testing of high power fuel cells. The system is equipped with a DC contactor on each pole (one in DC+ and one in DC-) to clearly separate the fuel cell from the system and to enable additional, useful functionalities. These include the active pre-charge, the reverse polarity detection and the zero current turn off functionality. In addition, the system has a temperature input to monitor the temperature of the fuel cell under test and to stop the test if the fuel cell becomes too hot. The system is installed with a high density into a 42U rack that has a width of only 600 mm and a depth of 1000 mm. The Rack has one AC input and is equipped with a 2 channel fast stop system to shut down the rack in emergency situations. The fast stop button is placed on the front of the door and the rear door is secured by door contact switches. Once the rear door opens during operation the fast stop system will be activated automatically. Also, the DC contactors are integrated into the fast stop system and disconnects the fuel cell tester from the fuel cell under test. |
|
| Download datasheet |
EA-BPTS 20920-720
| Manufacturer | EA - Elektro-Automatik |
| Power | 180000.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Available output range (V) | 0-920 |
EA-BPTS 20920-720
| Manufacturer |
|
| Power | 180000.00 W |
| Package | 42U |
| No. of outputs | 1 |
| Input voltage | 402 V, ±10% 3-phase |
| Efficiency | 0.00 |
| Available output range (V) | 0-920 |
| Output current (A) | 0-720 |
| Max output current | 0.00 |
| Electronic load input rating power | 0.00 |
| Dimensions | 600x42Ux1000mm |
| Weight | 650 |
| Water-cooled option | No |
Features:
|
|
| Description: The BPTS 20920-720 provides a powerful system for high capacity battery pack testing. The system works as a cycler device which can perform the function of charging and discharging. In discharge mode the device is regenerative and feeds the energy back into the local grid with an efficiency up to 96.5%. The DC power of 180 kW, the DC voltage of 0 - 920 V and the DC current of 0 - 720 A is tailored for the testing of high capacity battery packs. The system is equipped with a DC contactor on each pole (one in DC+ and one in DC-) to clearly separate the battery pack from the system and to enable additional, useful functionalities. These include the active pre-charge, the reverse polarity detection and the zero current turn off functionality. In addition, the system has a temperature input to monitor the temperature of the battery pack under test and to stop the test if the battery pack becomes too hot. The system is installed with a high density into a 42U rack that has a width of only 600 mm and a depth of 1000 mm. The Rack has one AC input and is equipped with a 2 channel fast stop system to shut down the rack in emergency situations. The fast stop button is placed on the front of the door and the rear door is secured by door contact switches. Once the rear door opens during operation the fast stop system will be activated automatically. Also, the DC contactors are integrated into the fast stop system and disconnects the pack tester from the battery pack under test. |
|
| Download datasheet |